8.0 CALIBRATION
The GBC/GFC scales are calibrated using metric weights and GBC/GFC-a
scales are calibrated using metric or pound weights depending on the
unit in use before calibration. See the Service parameters section for
more information.
The scale will display a value of the weight to be used for calibration, this
value is the last weight used for calibration. You can enter a different
value, if desired.
For entering Calibration, see section 7.0 Parameters
When “F1” “CAL” is displayed, press [Tare].
The display will then show "unLoAd" to request all weight be removed
from the platform.
Press the [Tare] key to set the zero point.
The displays will then show the calibration weight suggested, the value
is shown as an integer number, it is not possible to have fractions of a
kilogram or pound. For example:
LoAd 00004
KiLoS
Place the calibration weight on the platform. If the calibration weight is
different from the value shown, Press [CE] to clear the current value then
enter the correct value.
Press [Tare] to calibrate.
When calibration is done the display will show “SPAn” “PASS”.
Remove the weight. The scale will return to normal weighing.
If an error message SPAn” “FAIL” is displayed, then repeat the process.
After calibration, the scale should be checked whether the calibration is
correct. If necessary, repeat calibration.
NOTE: GBC/GFC-a scales will have the lb or kg indicator on, to show the unit of the
weight requested. If the scale was in pounds before starting the calibration, the
weights requested will be in pound values or if the scale was weighing in kilograms
then metric weights will be requested.
Page view 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 35 36

Comments to this Manuals

No comments